MIL-PRF-45307C(AT)
TABLE I. Classification of inspections.
Conformance
First
Exami- Accept-
Title
Requirement
Inspection
article
nation
ance
X
4.6.1
3.2 thru 3.3.4
Materials and construction
3.3, 3.3.1, 3.3.4,
Defects
X
X
4.4.1
3.5, 3.6 and 3.7
X
X
4.6.2.1
3.4.1
Volumetric efficiency
X
4.6.2.2
X
3.4.2
Hydraulic backlash
X
4.6.2.3
3.4.3
Proof pressure
X
4.6.2.4
X
3.4.4
Pump handle torque
4.6.2.5
X
X
3.4.5.1
Low pressure
4.6.2.5
X
X
3.4.5.2
High pressure
4.6.2.6
X
3.4.6
Low temperature
4.6.2.7
X
3.4.7
High temperature
4.6.2.8
3.4.8
X
Shock
TABLE II. Classification of defects.
Method of
Defect
examination
Category
Critical None
Major:
Visual
101
Nonconformance in design and construction (see 3.3
and 3.3.1).
SIE 1/
Dimensions affecting interchangeability out of
102
tolerance (see 3.3 and 3.3.4).
Faulty workmanship affecting performance (see 3.7).
Visual
103
Minor:
201
Dimensions not affecting interchangeability out of
SIE
tolerance (see 3.3).
202
Improper finish (see 3.5).
Visual
203
Improper marking (see 3.6).
Visual
204
Faulty workmanship affecting appearance (see 3.7).
Visual
1/ SIE = Standard Inspection Equipment.
4.5 Acceptance tests. Samples selected for acceptance tests in accordance with
ANSI/ASQC Z1.4 shall initially be examined in accordance with 4.4.1 and shall then be subjected
to the tests specified in table I.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business